Get complete information related to latest Chlorine Gas Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chlorine Gas Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chlorine Gas Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For supply and delivery of chlorinegas cylinders for treatment of water (maintenance of water supply) under mgf in nalgonda municipal corporation
Tender For corrigendum : cs/rmo/2026/2089-90/ac/washing - items, ac compressor 1-5 ton, ac compressor 2 ton, ac outdoor gas bal, ac indore fan motor, ac outdoor fan motor, ac condensers, ac gas charging, ac condenser outdoor mesh, connector ac, ac sensor indore, ac running capacitor, ac service charge, water cooler fan motor, water cooler compressor, water cooler condenser, water cooler mash, water cooler riley, water cooler over load, water cooler running capacitor, water cooler service charge, water cooler gas filling charge, washing machine spine timer, washing machine wash timer, washing machine wash motor, washing machine spine motor, washing machine bello, washing machine gear box, washing machine capacitor, washing machine service charge, refrigerator compressor, refrigerator rile, refrigerator overload, refrigerator thermometer, refrigerator senseor, refrigerator wall, refrigerator fan motor, refrigerator bimetal, refrigerator time, refrigerator pcv, refrigerator fuse, refrigerator door swath, refrigerator gas charge, refrigerator service charge, ac pcv, ac stand for spilit ac, ac stand for window ac, copper pipe for spilit ac per feet, copper pipe for window ac per feet, spilit and window ac remote
Tender For supply of cassette and split ac c c - cassette ac split ac , itc of ac , copper pipe, electrical cable, drain pipe , ms stand, indoor brackets, gas charging , ventilation work
Tender For supply of glass wares, polythene wares and miscellaneous items at ssctpp, suratgarh- bottle polythene (pp) wide mouth with cap , burette , burette clamp mild steel chrome pla type with boss head, single pkt (ea , center to (300mmx). , pipette bulbs , pipette stand horizontal (12 pip , retort stand , side hole (225mmx , side hole (300mmx , silicone pipette bulbs , volumetric flask , (ii)beaker polythene capacity 1000 ml,pp autoclaveable , (iii) beaker polythene capacity 250ml,pp autoclaveable , (iii)beaker polythene capacity 500 ml,pp autoclaveable , , , beaker polythene pp auto clavable , blow in low density polythene 125 ml , blow in low density polythene 60 ml , chloroform bladder 500 ml , dropper sterile capacity 3ml , dropping bottle , latex bladder enkay no,5 with clip , measuring cylinder , wash bottle ldpe plastic , , , circular capsules fused silica without lid 48 x 15 (20 ml) , dishes culture petri , crucible fused silica for vm + lid 25x22x38 mm , beaker grifin, low form, with spout, graduated , burette - boroflo, screw thread with ptfe key , funnel plain 60° angle long stem glass 100 mm diameter , funnel separating pear shape with hollow plug stop cock, hollow interchangeable stopper, 500ml , measuring cylinder-single matric scale with pour out , pipette measuring (mohr type) accuracy as per class -a , volumetric flask with stopper , 50 ml burette with 1 ltr. reservoir , automatic zero burette accuracy as per class a with certificate , bod bottles with i/c stopper (300 ml) , bottles reagent amber with i/c stopper , bottles reagent plain narrow mouth with flat head i/c stopper , conical flask , flask boiling round bottom , gas burette with jacket cap. 100 ml (graduated burette 0-5 ml least count 0.1 ml for orset appratus) , orsat gas analyser (for analysis of flue gases) for determination of co2 o2 and estimation of co in flue gases complete with rubber tubing connector. 50 ml burrete and other accessories equipment shall be complete polished wooden cabinet equipment should be made of heavy walled borosilicate glass tube and stop cock , spares parts for orsat apparatus , tissue paper roll (double ply) (whatman) filter paper, circular catno. , cellulose nitrate filter 0,45 micron , , acid proof suit , , coal sample tray 12"x 14" big , , spatula (one end spoon and one end flat) 200 mm , , safety goggles (plain) , , direct reading % thermometer for caustic soda lye (45% to 50%) w/w with temperature correction , bottle relative density with capillary bore interchangeable tefflon stopper, 25ml , chlorinegas toner spanner , direct reading % thermometer for hydrochloric acid (27% to 32%) w/w with temperature correction , direct reading % thermometer for sulphuric acid (95% to 99%) w/w with temperature correction , heating element for muffle furnace (1200 degree c , kanthal a-1 resisative wire) , lab apron coat, free size , relay for muffle furnance , spare parts for muffle furnace (make jd refractories) m degree , test sieve for coal analysis, brass frame s.s./wire mesh (make-jayant) , test sieve sets for coal mill fines will be brass, 200mm dia 50mm height, wire cloth from one piece without seam (set shall be consist of three sieve lid & receiver) 50, 100 and 200 astm mesh (make-jayant) , thermal fuse , thermocouple cr/al for muffle furnace , water bath rectangular (double wall), ambient to temp. 95°c, +/-1°c, 220/230v ac, 12 holes 75mm dia (size 425*325*100mm) , water safety jacket(medium size) , temperature controller (pid with sgr power controller) , , working chamber of muffle furnance 6x6x12 inch , , laboratory hand gloves , , laboratory hand gloves (rubber acid and alkali proof) medium size , , laboratory hand gloves nitrile , , polythene sampling bags , , polythene sampling bags (size-1 kg) with zip , , polythene sampling bags (size-500 gm) with zip , , polythene sampling bags (size-250 gm) with zip , , crucible tong , , crucible tong 12" inch , , crucible tong 24" inch , , gooch crucible g4 (size-30 ml) , , vm